The Dell Storage Center volume driver interacts with configured Storage Center arrays.
The Dell Storage Center driver manages Storage Center arrays through
the Dell Storage Manager (DSM). DSM connection settings and Storage
Center options are defined in the cinder.conf
file.
Prerequisite: Dell Storage Manager 2015 R1 or later must be used.
The Dell Storage Center volume driver provides the following Cinder volume operations:
Volume type extra specs can be used to enable a variety of Dell Storage Center options. Selecting Storage Profiles, Replay Profiles, enabling replication, replication options including Live Volume and Active Replay replication.
Storage Profiles control how Storage Center manages volume data. For a given volume, the selected Storage Profile dictates which disk tier accepts initial writes, as well as how data progression moves data between tiers to balance performance and cost. Predefined Storage Profiles are the most effective way to manage data in Storage Center.
By default, if no Storage Profile is specified in the volume extra
specs, the default Storage Profile for the user account configured for
the Block Storage driver is used. The extra spec key
storagetype:storageprofile
with the value of the name of the Storage
Profile on the Storage Center can be set to allow to use Storage
Profiles other than the default.
For ease of use from the command line, spaces in Storage Profile names
are ignored. As an example, here is how to define two volume types using
the High Priority
and Low Priority
Storage Profiles:
$ openstack volume type create "GoldVolumeType"
$ openstack volume type set --property storagetype:storageprofile=highpriority "GoldVolumeType"
$ openstack volume type create "BronzeVolumeType"
$ openstack volume type set --property storagetype:storageprofile=lowpriority "BronzeVolumeType"
Replay Profiles control how often the Storage Center takes a replay of a
given volume and how long those replays are kept. The default profile is
the daily
profile that sets the replay to occur once a day and to
persist for one week.
The extra spec key storagetype:replayprofiles
with the value of the
name of the Replay Profile or profiles on the Storage Center can be set
to allow to use Replay Profiles other than the default daily
profile.
As an example, here is how to define a volume type using the hourly
Replay Profile and another specifying both hourly
and the default
daily
profile:
$ openstack volume type create "HourlyType"
$ openstack volume type set --property storagetype:replayprofile=hourly "HourlyType"
$ openstack volume type create "HourlyAndDailyType"
$ openstack volume type set --property storagetype:replayprofiles=hourly,daily "HourlyAndDailyType"
Note the comma separated string for the HourlyAndDailyType
.
Replication for a given volume type is enabled via the extra spec
replication_enabled
.
To create a volume type that specifies only replication enabled back ends:
$ openstack volume type create "ReplicationType"
$ openstack volume type set --property replication_enabled='<is> True' "ReplicationType"
Extra specs can be used to configure replication. In addition to the Replay
Profiles above, replication:activereplay
can be set to enable replication
of the volume’s active replay. And the replication type can be changed to
synchronous via the replication_type
extra spec can be set.
To create a volume type that enables replication of the active replay:
$ openstack volume type create "ReplicationType"
$ openstack volume type key --property replication_enabled='<is> True' "ReplicationType"
$ openstack volume type key --property replication:activereplay='<is> True' "ReplicationType"
To create a volume type that enables synchronous replication :
$ openstack volume type create "ReplicationType"
$ openstack volume type key --property replication_enabled='<is> True' "ReplicationType"
$ openstack volume type key --property replication_type='<is> sync' "ReplicationType"
To create a volume type that enables replication using Live Volume:
$ openstack volume type create "ReplicationType"
$ openstack volume type key --property replication_enabled='<is> True' "ReplicationType"
$ openstack volume type key --property replication:livevolume='<is> True' "ReplicationType"
If QOS options are enabled on the Storage Center they can be enabled via extra
specs. The name of the Volume QOS can be specified via the
storagetype:volumeqos
extra spec. Likewise the name of the Group QOS to
use can be specificed via the storagetype:groupqos
extra spec. Volumes
created with these extra specs set will be added to the specified QOS groups.
To create a volume type that sets both Volume and Group QOS:
$ openstack volume type create "StorageCenterQOS"
$ openstack volume type key --property 'storagetype:volumeqos'='unlimited' "StorageCenterQOS"
$ openstack volume type key --property 'storagetype:groupqos'='limited' "StorageCenterQOS"
Data reduction profiles can be specified in the
storagetype:datareductionprofile
extra spec. Available options are None,
Compression, and Deduplication. Note that not all options are available on
every Storage Center.
To create volume types that support no compression, compression, and deduplication and compression respectively:
$ openstack volume type create "NoCompressionType"
$ openstack volume type key --property 'storagetype:datareductionprofile'='None' "NoCompressionType"
$ openstack volume type create "CompressedType"
$ openstack volume type key --property 'storagetype:datareductionprofile'='Compression' "CompressedType"
$ openstack volume type create "DedupType"
$ openstack volume type key --property 'storagetype:datareductionprofile'='Deduplication' "DedupType"
Note: The default is no compression.
Use the following instructions to update the configuration file for iSCSI:
default_volume_type = delliscsi
enabled_backends = delliscsi
[delliscsi]
# Name to give this storage back-end
volume_backend_name = delliscsi
# The iSCSI driver to load
volume_driver = cinder.volume.drivers.dell.dell_storagecenter_iscsi.DellStorageCenterISCSIDriver
# IP address of DSM
san_ip = 172.23.8.101
# DSM user name
san_login = Admin
# DSM password
san_password = secret
# The Storage Center serial number to use
dell_sc_ssn = 64702
# ==Optional settings==
# The DSM API port
dell_sc_api_port = 3033
# Server folder to place new server definitions
dell_sc_server_folder = devstacksrv
# Volume folder to place created volumes
dell_sc_volume_folder = devstackvol/Cinder
Use the following instructions to update the configuration file for fibre channel:
default_volume_type = dellfc
enabled_backends = dellfc
[dellfc]
# Name to give this storage back-end
volume_backend_name = dellfc
# The FC driver to load
volume_driver = cinder.volume.drivers.dell.dell_storagecenter_fc.DellStorageCenterFCDriver
# IP address of the DSM
san_ip = 172.23.8.101
# DSM user name
san_login = Admin
# DSM password
san_password = secret
# The Storage Center serial number to use
dell_sc_ssn = 64702
# ==Optional settings==
# The DSM API port
dell_sc_api_port = 3033
# Server folder to place new server definitions
dell_sc_server_folder = devstacksrv
# Volume folder to place created volumes
dell_sc_volume_folder = devstackvol/Cinder
It is possible to specify a secondary DSM to use in case the primary DSM fails.
Configuration is done through the cinder.conf. Both DSMs have to be configured to manage the same set of Storage Centers for this backend. That means the dell_sc_ssn and any Storage Centers used for replication or Live Volume.
Add network and credential information to the backend to enable Dual DSM.
[dell]
# The IP address and port of the secondary DSM.
secondary_san_ip = 192.168.0.102
secondary_sc_api_port = 3033
# Specify credentials for the secondary DSM.
secondary_san_login = Admin
secondary_san_password = secret
The driver will use the primary until a failure. At that point it will attempt to use the secondary. It will continue to use the secondary until the volume service is restarted or the secondary fails at which point it will attempt to use the primary.
Add the following to the back-end specification to specify another Storage Center to replicate to.
[dell]
replication_device = target_device_id: 65495, qosnode: cinderqos
The target_device_id
is the SSN of the remote Storage Center and the
qosnode
is the QoS Node setup between the two Storage Centers.
Note that more than one replication_device
line can be added. This will
slow things down, however.
A volume is only replicated if the volume is of a volume-type that has
the extra spec replication_enabled
set to <is> True
.
This driver supports both standard replication and Live Volume (if supported and licensed). The main difference is that a VM attached to a Live Volume is mapped to both Storage Centers. In the case of a failure of the primary Live Volume still requires a failover-host to move control of the volume to the second controller.
Existing mappings should work and not require the instance to be remapped but it might need to be rebooted.
Live Volume is more resource intensive than replication. One should be sure to plan accordingly.
The failover-host command is designed for the case where the primary system is not coming back. If it has been executed and the primary has been restored it is possible to attempt a failback.
Simply specify default as the backend_id.
$ cinder failover-host cinder@delliscsi --backend_id default
Non trivial heavy lifting is done by this command. It attempts to recover best it can but if things have diverged to far it can only do so much. It is also a one time only command so do not reboot or restart the service in the middle of it.
Failover and failback are significant operations under OpenStack Cinder. Be sure to consult with support before attempting.
This option allows one to set a default Server OS type to use when creating a server definition on the Dell Storage Center.
When attaching a volume to a node the Dell Storage Center driver creates a server definition on the storage array. This defition includes a Server OS type. The type used by the Dell Storage Center cinder driver is “Red Hat Linux 6.x”. This is a modern operating system definition that supports all the features of an OpenStack node.
Add the following to the back-end specification to specify the Server OS to use when creating a server definition. The server type used must come from the drop down list in the DSM.
[dell]
dell_server_os = 'Red Hat Linux 7.x'
Note that this server definition is created once. Changing this setting after the fact will not change an existing definition. The selected Server OS does not have to match the actual OS used on the node.
This option excludes a Storage Center ISCSI fault domain from the ISCSI properties returned by the initialize_connection call. This only applies to the ISCSI driver.
Add the excluded_domain_ip option into the backend config for each fault domain to be excluded. This option takes the specified Target IPv4 Address listed under the fault domain. Older versions of DSM (EM) may list this as the Well Known IP Address.
Add the following to the back-end specification to exclude the domains at 172.20.25.15 and 172.20.26.15.
[dell]
excluded_domain_ip=172.20.25.15
excluded_domain_ip=172.20.26.15
The following table contains the configuration options specific to the Dell Storage Center volume driver.
Configuration option = Default value | Description |
---|---|
[DEFAULT] | |
dell_sc_api_port = 3033 |
(Port number) Dell API port |
dell_sc_server_folder = openstack |
(String) Name of the server folder to use on the Storage Center |
dell_sc_ssn = 64702 |
(Integer) Storage Center System Serial Number |
dell_sc_verify_cert = False |
(Boolean) Enable HTTPS SC certificate verification |
dell_sc_volume_folder = openstack |
(String) Name of the volume folder to use on the Storage Center |
dell_server_os = Red Hat Linux 6.x |
(String) Server OS type to use when creating a new server on the Storage Center. |
excluded_domain_ip = None |
(Unknown) Domain IP to be excluded from iSCSI returns. |
secondary_san_ip = |
(String) IP address of secondary DSM controller |
secondary_san_login = Admin |
(String) Secondary DSM user name |
secondary_san_password = |
(String) Secondary DSM user password name |
secondary_sc_api_port = 3033 |
(Port number) Secondary Dell API port |