Dell EMC PowerVault ME4 Series Fibre Channel and iSCSI drivers¶
The PVMEFCDriver
and PVMEISCSIDriver
Cinder drivers allow the
Dell EMC PowerVault ME4 Series storage arrays to be used for Block
Storage in OpenStack deployments.
System requirements¶
To use the PowerVault ME4 Series drivers, the following are required:
PowerVault ME4 Series storage array with:
iSCSI or FC host interfaces
G28x firmware or later
Network connectivity between the OpenStack hosts and the array’s embedded management interface
The HTTPS protocol must be enabled on the array
Supported operations¶
Create, delete, attach, and detach volumes.
Create, list, and delete volume snapshots.
Create a volume from a snapshot.
Copy an image to a volume.
Copy a volume to an image.
Clone a volume.
Extend a volume.
Migrate a volume with back-end assistance.
Retype a volume.
Manage and unmanage a volume.
Configuring the array¶
Verify that the array can be managed via an HTTPS connection. HTTP can also be used if
driver_use_ssl
is set to False in thecinder.conf
file.Confirm that virtual pools A and B are already present on the array. If they are missing, create them.
Edit the
cinder.conf
file to define a storage back-end entry for each storage pool on the array that will be managed by OpenStack. Each entry consists of a unique section name, surrounded by square brackets, followed by options specified in akey=value
format.The
pvme_pool_name
value specifies the name of the storage pool or vdisk on the array.The
volume_backend_name
option value can be a unique value, if you wish to be able to assign volumes to a specific storage pool on the array, or a name that is shared among multiple storage pools to let the volume scheduler choose where new volumes are allocated.
The following
cinder.conf
options generally have identical values for each backend section on the array:volume_driver
specifies the Cinder driver name.san_ip
specifies the IP addresses or host names of the array’s management controllers.san_login
andsan_password
specify the username and password of an array user account withmanage
privilegesdriver_use_ssl
must be set to True to enable use of the HTTPS protocol.pvme_iscsi_ips
specifies the iSCSI IP addresses for the array if using the iSCSI transport protocol
In the examples below, two back ends are defined, one for pool A and one for pool B, and a common
volume_backend_name
is used so that a single volume type definition can be used to allocate volumes from both pools.iSCSI example back-end entries
[pool-a] pvme_pool_name = A volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.iscsi.PVMEISCSIDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage pvme_iscsi_ips = 10.2.3.4,10.2.3.5 driver_use_ssl = true [pool-b] pvme_pool_name = B volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.iscsi.PVMEISCSIDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage pvme_iscsi_ips = 10.2.3.4,10.2.3.5 driver_use_ssl = true
Fibre Channel example back-end entries
[pool-a] pvme_pool_name = A volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.fc.PVMEFCDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage driver_use_ssl = true [pool-b] pvme_pool_name = B volume_backend_name = pvme-array volume_driver = cinder.volume.drivers.dell_emc.powervault.fc.PVMEFCDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage driver_use_ssl = true
If HTTPS is enabled, you can enable certificate verification with the option
driver_ssl_cert_verify = True
. You may also use thedriver_ssl_cert_path
parameter to specify the path to a CA_BUNDLE file containing CAs other than those in the default list.Modify the
[DEFAULT]
section of thecinder.conf
file to add anenabled_backends
parameter specifying the backend entries you added, and adefault_volume_type
parameter specifying the name of a volume type that you will create in the next step.Example of [DEFAULT] section changes
[DEFAULT] enabled_backends = pool-a,pool-b default_volume_type = pvme
Create a new volume type for each distinct
volume_backend_name
value that you added in thecinder.conf
file. The example below assumes that the samevolume_backend_name=pvme-array
option was specified in all of the entries, and specifies that the volume typepvme
can be used to allocate volumes from any of them.Example of creating a volume type
$ openstack volume type create pvme $ openstack volume type set --property volume_backend_name=pvme-array pvme
After modifying the
cinder.conf
file, restart thecinder-volume
service.
Driver-specific options¶
The following table contains the configuration options that are specific to the PowerVault ME Series drivers.
Configuration option = Default value |
Description |
---|---|
|
(List of String) List of comma-separated target iSCSI IP addresses. |
|
(String) Pool or Vdisk name to use for volume creation. |