HPE MSA Fibre Channel and iSCSI drivers¶
The HPMSAFCDriver
and HPMSAISCSIDriver
Cinder drivers allow the
HPE MSA 2050, 1050, 2040, and 1040 arrays to be used for Block Storage in
OpenStack deployments.
System requirements¶
To use the HP MSA drivers, the following are required:
HPE MSA 2050, 1050, 2040 or 1040 array with:
iSCSI or FC host interfaces
G22x firmware or later
Network connectivity between the OpenStack host and the array management interfaces
HTTPS or HTTP must be enabled on the array
Supported operations¶
Create, delete, attach, and detach volumes.
Create, list, and delete volume snapshots.
Create a volume from a snapshot.
Copy an image to a volume.
Copy a volume to an image.
Clone a volume.
Extend a volume.
Migrate a volume with back-end assistance.
Retype a volume.
Manage and unmanage a volume.
Configuring the array¶
Verify that the array can be managed using an HTTPS connection. HTTP can also be used if
hpmsa_api_protocol=http
is placed into the appropriate sections of thecinder.conf
file, but this option is deprecated and will be removed in a future release.Confirm that virtual pools A and B are present if you plan to use virtual pools for OpenStack storage.
If you plan to use vdisks instead of virtual pools, create or identify one or more vdisks to be used for OpenStack storage; typically this will mean creating or setting aside one disk group for each of the A and B controllers.
Edit the
cinder.conf
file to define a storage back-end entry for each storage pool on the array that will be managed by OpenStack. Each entry consists of a unique section name, surrounded by square brackets, followed by options specified inkey=value
format.The
hpmsa_pool_name
value specifies the name of the storage pool or vdisk on the array.The
volume_backend_name
option value can be a unique value, if you wish to be able to assign volumes to a specific storage pool on the array, or a name that is shared among multiple storage pools to let the volume scheduler choose where new volumes are allocated.The rest of the options will be repeated for each storage pool in a given array:
volume_driver
specifies the Cinder driver name.san_ip
specifies the IP addresses or host names of the array’s management controllers.san_login
andsan_password
specify the username and password of an array user account withmanage
privileges.driver_use_ssl
should be set totrue
to enable use of the HTTPS protocol.hpmsa_iscsi_ips
specifies the iSCSI IP addresses for the array if using the iSCSI transport protocol.
In the examples below, two back ends are defined, one for pool A and one for pool B, and a common
volume_backend_name
is used so that a single volume type definition can be used to allocate volumes from both pools.Example: iSCSI example back-end entries
[pool-a] hpmsa_pool_name = A volume_backend_name = hpmsa-array volume_driver = cinder.volume.drivers.san.hp.hpmsa_iscsi.HPMSAISCSIDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage hpmsa_iscsi_ips = 10.2.3.4,10.2.3.5 driver_use_ssl = true [pool-b] hpmsa_pool_name = B volume_backend_name = hpmsa-array volume_driver = cinder.volume.drivers.san.hp.hpmsa_iscsi.HPMSAISCSIDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage hpmsa_iscsi_ips = 10.2.3.4,10.2.3.5 driver_use_ssl = true
Example: Fibre Channel example back-end entries
[pool-a] hpmsa_pool_name = A volume_backend_name = hpmsa-array volume_driver = cinder.volume.drivers.san.hp.hpmsa_fc.HPMSAFCDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage driver_use_ssl = true [pool-b] hpmsa_pool_name = B volume_backend_name = hpmsa-array volume_driver = cinder.volume.drivers.san.hp.hpmsa_fc.HPMSAFCDriver san_ip = 10.1.2.3,10.1.2.4 san_login = manage san_password = !manage driver_use_ssl = true
If any
volume_backend_name
value refers to a vdisk rather than a virtual pool, add an additional statementhpmsa_pool_type = linear
to that back end entry.If HTTPS is not enabled in the array, include
hpmsa_api_protocol = http
in each of the back-end definitions.If HTTPS is enabled, you can enable certificate verification with the option
driver_ssl_cert_verify = True
. You may also use thedriver_ssl_cert_path
option to specify the path to a CA_BUNDLE file containing CAs other than those in the default list.Modify the
[DEFAULT]
section of thecinder.conf
file to add anenabled_backends
parameter specifying the back-end entries you added, and adefault_volume_type
parameter specifying the name of a volume type that you will create in the next step.Example: [DEFAULT] section changes
[DEFAULT] # ... enabled_backends = pool-a,pool-b default_volume_type = hpmsa
Create a new volume type for each distinct
volume_backend_name
value that you added to thecinder.conf
file. The example below assumes that the samevolume_backend_name=hpmsa-array
option was specified in all of the entries, and specifies that the volume typehpmsa
can be used to allocate volumes from any of them.Example: Creating a volume type
$ openstack volume type create hpmsa $ openstack volume type set --property volume_backend_name=hpmsa-array hpmsa
After modifying the
cinder.conf
file, restart thecinder-volume
service.
Driver-specific options¶
The following table contains the configuration options that are specific to the HP MSA drivers.
Configuration option = Default value |
Description |
---|---|
|
(List of String) List of comma-separated target iSCSI IP addresses. |
|
(String) Pool or Vdisk name to use for volume creation. |
|
(String(choices=[‘linear’, ‘virtual’])) linear (for Vdisk) or virtual (for Pool). |
|
(String(choices=[‘http’, ‘https’])) HPMSA API interface protocol. DEPRECATED |
|
(Boolean) Whether to verify HPMSA array SSL certificate. DEPRECATED |
|
(String) HPMSA array SSL certificate path. DEPRECATED |