SNMP driver¶
The SNMP power driver enables control of power distribution units of the type frequently found in data centre racks. PDUs frequently have a management ethernet interface and SNMP support enabling control of the power outlets.
The SNMP power driver works with the PXE driver for network deployment and network-configured boot.
List of supported devices¶
This is a non-exhaustive list of supported devices. Any device not listed in this table could possibly work using a similar driver.
Please report any device status.
Manufacturer | Model | Supported? | Driver name |
---|---|---|---|
APC | AP7920 | Yes | apc_masterswitch |
APC | AP9606 | Yes | apc_masterswitch |
APC | AP9225 | Yes | apc_masterswitchplus |
APC | AP7155 | Yes | apc_rackpdu |
APC | AP7900 | Yes | apc_rackpdu |
APC | AP7901 | Yes | apc_rackpdu |
APC | AP7902 | Yes | apc_rackpdu |
APC | AP7911a | Yes | apc_rackpdu |
APC | AP7921 | Yes | apc_rackpdu |
APC | AP7922 | Yes | apc_rackpdu |
APC | AP7930 | Yes | apc_rackpdu |
APC | AP7931 | Yes | apc_rackpdu |
APC | AP7932 | Yes | apc_rackpdu |
APC | AP7940 | Yes | apc_rackpdu |
APC | AP7941 | Yes | apc_rackpdu |
APC | AP7951 | Yes | apc_rackpdu |
APC | AP7960 | Yes | apc_rackpdu |
APC | AP7990 | Yes | apc_rackpdu |
APC | AP7998 | Yes | apc_rackpdu |
APC | AP8941 | Yes | apc_rackpdu |
APC | AP8953 | Yes | apc_rackpdu |
APC | AP8959 | Yes | apc_rackpdu |
APC | AP8961 | Yes | apc_rackpdu |
APC | AP8965 | Yes | apc_rackpdu |
Aten | all? | Yes | aten |
CyberPower | all? | Untested | cyberpower |
EatonPower | all? | Untested | eatonpower |
Teltronix | all? | Yes | teltronix |
Software Requirements¶
- The PySNMP package must be installed, variously referred to as
pysnmp
orpython-pysnmp
Enabling the SNMP Power Driver¶
- Add
pxe_snmp
to the list ofenabled_drivers
in/etc/ironic/ironic.conf
- Ironic Conductor must be restarted for the new driver to be loaded.
Ironic Node Configuration¶
Nodes are configured for SNMP control by setting the Ironic node object’s
driver
property to be pxe_snmp
. Further configuration values are
added to driver_info
:
snmp_driver
: PDU manufacturer driversnmp_address
: the IPv4 address of the PDU controlling this node.snmp_port
: (optional) A non-standard UDP port to use for SNMP operations. If not specified, the default port (161) is used.snmp_outlet
: The power outlet on the PDU (1-based indexing).snmp_protocol
: (optional) SNMP protocol version (permitted values1
,2c
or3
). If not specified, SNMPv1 is chosen.snmp_community
: (Required for SNMPv1 and SNMPv2c) SNMP community parameter for reads and writes to the PDU.snmp_security
: (Required for SNMPv3) SNMP security string.
PDU Configuration¶
This version of the SNMP power driver does not support handling
PDU authentication credentials. When using SNMPv3, the PDU must be
configured for NoAuthentication
and NoEncryption
. The
security name is used analogously to the SNMP community in early
SNMP versions.