HP OneView [1] is a single integrated platform, packaged as an appliance that
implements a software-defined approach to managing physical infrastructure.
The appliance supports scenarios such as deploying bare metal servers, for
instance. In this context, the HP OneView driver
for ironic enables the
users of OneView to use ironic as a bare metal provider to their managed
physical hardware.
HPE OneView hardware is supported by the oneview
hardware type and the
following classic drivers:
iscsi_pxe_oneview
agent_pxe_oneview
The iscsi_pxe_oneview
and agent_pxe_oneview
drivers implement the core
interfaces of an ironic Driver [2], and use the hpOneView
[3] library
to provide communication between ironic and OneView through OneView’s REST API.
Note
Classic drivers will be deprecated in favor of Hardware Types.
To provide a bare metal instance there are four components involved in the process:
The role of ironic is to serve as a bare metal provider to OneView’s managed
physical hardware and to provide communication with other necessary OpenStack
services such as Nova and Glance. When ironic receives a boot request, it
works together with the ironic OneView driver to access a machine in OneView,
the hpOneView
being responsible for the communication with the OneView
appliance.
From the Newton release on, OneView drivers enables a new feature called dynamic allocation of nodes [6]. In this model, the driver allocates resources in OneView only at boot time, allowing idle resources in ironic to be used by OneView users, enabling actual resource sharing among ironic and OneView users.
Since OneView can claim nodes in available
state at any time, a set of
tasks runs periodically to detect nodes in use by OneView. A node in use by
OneView is placed in manageable
state and has maintenance mode set. Once
the node is no longer in use, these tasks will make place them back in
available
state and clear maintenance mode.
The following requirements apply for both iscsi_pxe_oneview
and
agent_pxe_oneview
drivers:
OneView appliance
is the HP physical infrastructure manager to be
integrated with the OneView drivers.
Minimum version supported is 2.0.
hpOneView
is a python package containing a client to manage the
communication between ironic and OneView.
Install the hpOneView
module to enable the communication. Minimum version
required is 4.4.0 but it is recommended to install the most up-to-date
version:
$ pip install "hpOneView>=4.4.0"
ironic-inspector
if using hardware inspection.
The OneView appliance used for testing was the OneView 2.0.
The Enclosure used for testing was the BladeSystem c7000 Enclosure G2
.
The drivers should work on HP Proliant Gen8 and Gen9 Servers supported by OneView 2.0 and above, or any hardware whose network can be managed by OneView’s ServerProfile. It has been tested with the following servers:
Notice that for the driver to work correctly with Gen8 and Gen9 DL servers in general, the hardware also needs to run version 4.2.3 of iLO, with Redfish enabled.
The oneview
hardware type supports the following hardware interfaces:
Supports only pxe
. It can be enabled by using the
[DEFAULT]enabled_boot_interfaces
option in ironic.conf
as given below:
[DEFAULT]
enabled_hardware_types = oneview
enabled_boot_interfaces = pxe
Supports only no-console
. It can be enabled by using the
[DEFAULT]enabled_console_interfaces
option in ironic.conf
as given below:
[DEFAULT]
enabled_hardware_types = oneview
enabled_console_interfaces = no-console
Supports oneview-direct
and oneview-iscsi
. The default is
oneview-iscsi
. They can be enabled by using the
[DEFAULT]enabled_deploy_interfaces
option in ironic.conf
as given below:
[DEFAULT]
enabled_hardware_types = oneview
enabled_deploy_interfaces = oneview-iscsi,oneview-direct
Supports oneview
and no-inspect
. The default is oneview
.
They can be enabled by using the [DEFAULT]enabled_inspect_interfaces
option in ironic.conf
as given below:
[DEFAULT]
enabled_hardware_types = oneview
enabled_inspect_interfaces = oneview,no-inspect
Supports only oneview
. It can be enabled by using the
[DEFAULT]enabled_management_interfaces
option in ironic.conf
as
given below:
[DEFAULT]
enabled_hardware_types = oneview
enabled_management_interfaces = oneview
Supports only oneview
. It can be enabled by using the
[DEFAULT]enabled_power_interfaces
option in ironic.conf
as given
below:
[DEFAULT]
enabled_hardware_types = oneview
enabled_power_interfaces = oneview
The oneview
hardware type also supports the standard network and
storage interfaces.
To enable the same feature set as provided by all oneview classic drivers, apply the following configuration:
[DEFAULT]
enabled_hardware_types = oneview
enabled_deploy_interfaces = oneview-direct,oneview-iscsi
enabled_inspect_interfaces = oneview
enabled_power_interfaces = oneview
enabled_management_interfaces = oneview
The following commands can be used to enroll a node with the same
feature set as one of the classic drivers, but using the oneview
hardware type:
oneview-direct
:
openstack baremetal node create --os-baremetal-api-version=1.31 \
--driver oneview \
--deploy-interface oneview-direct
oneview-iscsi
:
openstack baremetal node create --os-baremetal-api-version=1.31 \
--driver oneview \
--deploy-interface oneview-iscsi
iscsi_pxe_oneview
driver uses PXEBoot for boot and ISCSIDeploy for deploy.
Add iscsi_pxe_oneview
to the list of enabled_drivers
in your
ironic.conf
file. For example:
enabled_drivers = iscsi_pxe_oneview
Update the [oneview] section of your ironic.conf
file with your
OneView credentials and CA certificate files information.
Note
An operator can set the periodic_check_interval
option in the [oneview]
section to set the interval between running the periodic check. The default
value is 300 seconds (5 minutes). A lower value will reduce the likelihood
of races between ironic and OneView at the cost of being more resource
intensive.
Restart the ironic conductor service. For Ubuntu users, do:
$ sudo service ironic-conductor restart
See Bare Metal Service Installation Guide for more information.
Here is an overview of the deploy process for this driver:
iscsi_pxe_oneview
driver.agent_pxe_oneview
driver uses PXEBoot for boot and AgentDeploy for deploy.
Add agent_pxe_oneview
to the list of enabled_drivers
in your
ironic.conf
. For example:
enabled_drivers = fake,pxe_ipmitool,agent_pxe_oneview
Update the [oneview] section of your ironic.conf
file with your
OneView credentials and CA certificate files information.
Note
An operator can set the periodic_check_interval
option in the [oneview]
section to set the interval between running the periodic check. The default
value is 300 seconds (5 minutes). A lower value will reduce the likelihood
of races between ironic and OneView at the cost of being more resource
intensive.
Restart the ironic conductor service. For Ubuntu users, do:
$ service ironic-conductor restart
See Bare Metal Service Installation Guide for more information.
Here is an overview of the deploy process for this driver:
agent_pxe_oneview
driver.OneView drivers for ironic have the ability to do hardware inspection.
Hardware inspection is the process of discovering hardware properties like
memory size, CPU cores, processor architecture and disk size, of a given
hardware. OneView drivers do in-band inspection, that involves booting a
ramdisk on the hardware and fetching information directly from it. For that,
your cloud controller needs to have the ironic-inspector
component
[9] running and properly enabled in ironic’s configuration file.
See [10] for more information on how to install and configure
ironic-inspector
.
Nodes configured to use any of the OneView drivers should have the driver
property set to iscsi_pxe_oneview
or agent_pxe_oneview
. Considering
our context, a node is the representation of a Server Hardware
in OneView,
and should be consistent with all its properties and related components, such
as Server Hardware Type
, Server Profile Template
, Enclosure Group
,
etc. In this case, to be enrolled, the node must have the following parameters:
driver_info
server_hardware_uri
: URI of the Server Hardware
on OneView.properties/capabilities
server_hardware_type_uri
: URI of the Server Hardware Type
of the
Server Hardware
.server_profile_template_uri
: URI of the Server Profile Template
used
to create the Server Profile
of the Server Hardware
.enclosure_group_uri
(optional): URI of the Enclosure Group
of the
Server Hardware
.To enroll a node with any of the OneView drivers, do:
$ openstack baremetal node create --driver $DRIVER_NAME
To update the driver_info
field of a newly enrolled OneView node, do:
$ openstack baremetal node set $NODE_UUID --driver-info server_hardware_uri=$SH_URI
To update the properties/capabilities
namespace of a newly enrolled
OneView node, do:
$ openstack baremetal node set $NODE_UUID \
--property capabilities=server_hardware_type_uri:$SHT_URI,enclosure_group_uri:$EG_URI,server_profile_template_uri=$SPT_URI
In order to deploy, ironic will create and apply, at boot time, a Server
Profile
based on the Server Profile Template
specified on the node to the
Server Hardware
it represents on OneView. The URI of such Server Profile
will be stored in driver_info.applied_server_profile_uri
field while the
Server is allocated to ironic.
The Server Profile Templates
and, therefore, the Server Profiles
derived
from them MUST comply with the following requirements:
Server Profile
/Server Profile Template
should be set to Physical
option;Node ports should be created considering the MAC address of the first
Interface of the given Server Hardware
.
To tell ironic which NIC should be connected to the provisioning network, do:
$ openstack baremetal port create --node $NODE_UUID $MAC_ADDRESS
For more information on the enrollment process of an ironic node, see Enrollment.
For more information on the definitions of Server Hardware
, Server
Profile
, Server Profile Template
and other OneView entities, refer to
[1] or browse Help in your OneView appliance menu.
Note
Ironic manages OneView machines either when they have a Server Profile applied by the driver or when they don’t have any Server Profile. Trying to change the power state of the machine in OneView without first assigning a Server Profile will lead to allowing Ironic to revert the power state change. Ironic will NOT change the power state of machines which the Server Profile was applied by another OneView user.
In order to ease user manual tasks, which are often time-consuming, we provide useful tools that work nicely with the OneView drivers.
The ironic-oneView
CLI is a command line interface for management tasks
involving OneView nodes. Its features include a facility to create of ironic
nodes with all required parameters for OneView nodes, creation of Nova flavors
for OneView nodes.
For more details on how Ironic-OneView CLI works and how to set it up, see [8].
[1] | (1, 2) HP OneView - https://www.hpe.com/us/en/integrated-systems/software.html |
[2] | Drivers |
[3] | hpOneView - https://pypi.python.org/pypi/hpOneView |
[6] | Dynamic Allocation in OneView drivers - http://specs.openstack.org/openstack/ironic-specs/specs/not-implemented/oneview-drivers-dynamic-allocation.html |
[7] | ironic-oneviewd - https://pypi.python.org/pypi/ironic-oneviewd/ |
[8] | ironic-oneview-cli - https://pypi.python.org/pypi/ironic-oneview-cli/ |
[9] | ironic-inspector - https://docs.openstack.org/ironic-inspector/latest/ |
[10] | ironic-inspector install - https://docs.openstack.org/ironic-inspector/latest/install/index.html |
Except where otherwise noted, this document is licensed under Creative Commons Attribution 3.0 License. See all OpenStack Legal Documents.