SNMP driver¶
The SNMP hardware type enables control of power distribution units of the type frequently found in data centre racks. PDUs frequently have a management ethernet interface and SNMP support enabling control of the power outlets.
The SNMP power interface works with the PXE boot interface for network deployment and network-configured boot.
Note
Unlike most of the other power interfaces, the SNMP power interface does
not have a corresponding management interface. The SNMP hardware type uses
the noop
management interface instead.
List of supported devices¶
This is a non-exhaustive list of supported devices. Any device not listed in this table could possibly work using a similar driver.
Please report any device status.
Manufacturer |
Model |
Supported? |
Driver name |
---|---|---|---|
APC |
AP7920 |
Yes |
apc_masterswitch |
APC |
AP9606 |
Yes |
apc_masterswitch |
APC |
AP9225 |
Yes |
apc_masterswitchplus |
APC |
AP7155 |
Yes |
apc_rackpdu |
APC |
AP7900 |
Yes |
apc_rackpdu |
APC |
AP7901 |
Yes |
apc_rackpdu |
APC |
AP7902 |
Yes |
apc_rackpdu |
APC |
AP7911a |
Yes |
apc_rackpdu |
APC |
AP7921 |
Yes |
apc_rackpdu |
APC |
AP7922 |
Yes |
apc_rackpdu |
APC |
AP7930 |
Yes |
apc_rackpdu |
APC |
AP7931 |
Yes |
apc_rackpdu |
APC |
AP7932 |
Yes |
apc_rackpdu |
APC |
AP7940 |
Yes |
apc_rackpdu |
APC |
AP7941 |
Yes |
apc_rackpdu |
APC |
AP7951 |
Yes |
apc_rackpdu |
APC |
AP7960 |
Yes |
apc_rackpdu |
APC |
AP7990 |
Yes |
apc_rackpdu |
APC |
AP7998 |
Yes |
apc_rackpdu |
APC |
AP8941 |
Yes |
apc_rackpdu |
APC |
AP8953 |
Yes |
apc_rackpdu |
APC |
AP8959 |
Yes |
apc_rackpdu |
APC |
AP8961 |
Yes |
apc_rackpdu |
APC |
AP8965 |
Yes |
apc_rackpdu |
Aten |
all? |
Yes |
aten |
CyberPower |
all? |
Untested |
cyberpower |
EatonPower |
all? |
Untested |
eatonpower |
Teltronix |
all? |
Yes |
teltronix |
BayTech |
MRP27 |
Yes |
baytech_mrp27 |
Software Requirements¶
The PySNMP package must be installed, variously referred to as
pysnmp
orpython-pysnmp
Enabling the SNMP Hardware Type¶
Add
snmp
to the list ofenabled_hardware_types
inironic.conf
. Also updateenabled_management_interfaces
andenabled_power_interfaces
inironic.conf
as shown below:[DEFAULT] enabled_hardware_types = snmp enabled_management_interfaces = noop enabled_power_interfaces = snmp
To set the default boot option, update
default_boot_option
inironic.conf
:[DEFAULT] default_boot_option = netboot
Note
Currently the default value of
default_boot_option
isnetboot
but it will be changed tolocal
in the future. It is recommended to set an explicit value for this option.Note
It is important to set
boot_option
tonetboot
as SNMP hardware type does not support setting of boot devices. One can also configure a node to boot usingnetboot
by setting itscapabilities
and updating Nova flavor as described below:openstack baremetal node set --property capabilities="boot_option:netboot" <node-uuid> openstack flavor set --property "capabilities:boot_option"="netboot" ironic-flavor
Restart the Ironic conductor service.
service ironic-conductor restart
Ironic Node Configuration¶
Nodes configured to use the SNMP hardware type should have the driver
field
set to the hardware type snmp
.
The following property values have to be added to the node’s
driver_info
field:
snmp_driver
: PDU manufacturer driver name orauto
to automatically choose ironic snmp driver based onSNMPv2-MIB::sysObjectID
value as reported by PDU.snmp_address
: the IPv4 address of the PDU controlling this node.snmp_port
: (optional) A non-standard UDP port to use for SNMP operations. If not specified, the default port (161) is used.snmp_outlet
: The power outlet on the PDU (1-based indexing).snmp_version
: (optional) SNMP protocol version (permitted values1
,2c
or3
). If not specified, SNMPv1 is chosen.snmp_community
: (Required for SNMPv1/SNMPv2c unlesssnmp_community_read
and/orsnmp_community_write
properties are present in which case the latter take over) SNMP community name parameter for reads and writes to the PDU.snmp_community_read
: SNMP community name parameter for reads to the PDU. Takes precedence over thesnmp_community
property.snmp_community_write
: SNMP community name parameter for writes to the PDU. Takes precedence over thesnmp_community
property.snmp_user
: (Required for SNMPv3) SNMPv3 User-based Security Model (USM) user name. Synonym for now obsoletesnmp_security
parameter.snmp_auth_protocol
: SNMPv3 message authentication protocol ID. Valid values include:none
,md5
,sha
for all pysnmp versions and additionallysha224
,sha256
,sha384
,sha512
for pysnmp versions 4.4.1 and later. Default isnone
unlesssnmp_auth_key
is provided. In the latter casemd5
is the default.snmp_auth_key
: SNMPv3 message authentication key. Must be 8+ characters long. Required when message authentication is used.snmp_priv_protocol
: SNMPv3 message privacy (encryption) protocol ID. Valid values include:none
,des
,3des
,aes
,aes192
,aes256
for all pysnmp version and additionallyaes192blmt
,aes256blmt
for pysnmp versions 4.4.3+. Note that message privacy requires using message authentication. Default isnone
unlesssnmp_priv_key
is provided. In the latter casedes
is the default.snmp_priv_key
: SNMPv3 message privacy (encryption) key. Must be 8+ characters long. Required when message encryption is used.snmp_context_engine_id
: SNMPv3 context engine ID. Default is the value of authoritative engine ID.snmp_context_name
: SNMPv3 context name. Default is an empty string.
The following command can be used to enroll a node with the snmp
hardware
type:
openstack baremetal node create --os-baremetal-api-version=1.31 \
--driver snmp --driver-info snmp_driver=<pdu_manufacturer> \
--driver-info snmp_address=<ip_address> \
--driver-info snmp_outlet=<outlet_index> \
--driver-info snmp_community=<community_string> \
--properties capabilities=boot_option:netboot