VNF AutoHealing triggered by FaultNotification¶
Overview¶
Tacker supports AutoHealing
using FaultNotification
interface.
When fault events occur in VIM, VIM notifies fault event to Tacker via
the interface. Tacker takes initiative of AutoHealing. Tacker checks
faultID attribute in the fault event and determines whether
AutoHealing should be performed. In case of performing AutoHealing,
VMs are deleted or created.
Configuration¶
FaultNotification is disabled by default.
To enable FaultNotification, be sure to set true for
CONF.server_notification.server_notification
.
Configuration (CONF.server_notification) |
Default |
Description |
---|---|---|
|
false |
Enable FaultNotification interface. |
|
/server_notification |
Uri path prefix string for FaultNotification interface. When changing this configuration, server_notification description in api-paste.ini must be changed to the same value. |
|
20 |
When multiple fault events for a vnf instance are
notified in the |
System¶
FaultNotification AutoHealing needs external service called Server Notifier.
The Server Notifier
is a monitoring service that is implemented
by each operators, thus it is not included in Tacker.
When the Server Notifier detects fault events in VIM, it will send
FaultNotification to Tacker.
Setting FaultNotification interface uri or enabling monitoring
for the Server Notifier is performed along the vnf lifecycle.
So Tacker provides a sample implementation of the mgmt driver script
to achieve interface registration and enabling monitoring.
+--------------------------+
| Client (NFVO) +--------+
+--------------------------+ | 1. Vnf instantiation
+-----------------------------------v--------------------------------+
| 2.Create VM Tacker |
6.FaultNotification | 3.Interface registration (in mgmt driver) |
+--------------> 7.Perform Healing |
| | 8.Delete failed VM and Create new VM |
| +---------------------------------------+-------------+--------------+
| +----------------------------------------------+ |
+------|-------|------------------------------------------------------------|--------------+
| | | 4.Start monitoring +---------------+--------+ VIM/NFVI |
| | | | | |
| +--+-------v--+ +--------v----+ +------v------+ |
| | Server | 5.Detects fault event | +--------+ | | +--------+ | |
| | Notifier +-------------------------> VNF | | | | VNF | | |
| | | | +--------+ | | +--------+ | |
| | | | VM | | VM | |
| +-------------+ +-------------+ +-------------+ |
+------------------------------------------------------------------------------------------+
For details about the interface, please refer to Fault Notification Interface.
Mgmt driver script¶
Sample mgmt driver script to achieve
interface registration and enabling monitoring is
tacker/sol_refactored/mgmt_drivers/server_notification.py
Put this script into target VNF package and Server Notifier can detect fault event on the VNF.
LCM interface¶
The LCM interface is modified to set parameters for Server Notifier.
The additionalParams
must be set when using FaultNotification.
- Name: Instantiate VNF taskDescription: This task resource represents the
Instantiate VNF
operation. The client can use this resource to instantiate a VNF instance.Only the additionalParams and the vnfConfigurableProperties for FaultNotification are described here
.Method type: POSTURL for the resource: /vnflcm/v2/vnf_instances/{vnfInstanceId}/instantiateRequest:Attribute name (InstantiateVnfRequest)
Data type
Cardinality
Description
vnfConfigurableProperties
KeyValuePairs
0..1
Additional VNF-specific attributes that provide the current values of the configurable properties of the VNF instance.
additionalParams
KeyValuePairs
0..1
Additional input parameters for the instantiation process, specific to the VNF being instantiated.
Attribute name (vnfConfigurableProperties)
Data type
Cardinality
Description
isAutohealEnabled
boolean
0..1
If present, the VNF supports auto-healing. If set to true, auto-healing is currently enabled. If set to false, autohealing is currently disabled.
Attribute name (additionalParams)
Data type
Cardinality
Description
ServerNotifierUri
String
1
Base Uri for ServerNotifier.
ServerNotifierFaultID
String
1..N
List of string that indicates which type of alarms to detect.
The value of ServerNotifierUri
and ServerNotifierFaultID
are stored
in instantiatedVnfInfo
of vnfInstance. The values can be shown
with vnflcm show command. For example:
$ openstack vnflcm show 6fd264ea-78fb-4862-90c0-1a9597734d95 --os-tacker-api-version 2
+-----------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Field | Value |
+-----------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| ID | 6fd264ea-78fb-4862-90c0-1a9597734d95 |
| Instantiated Vnf Info | { |
| | .... |
| | "metadata": { |
| | "ServerNotifierUri": "http://localhost:9990/server_notification", |
| | "ServerNotifierFaultID": ["1111", "1234"] |
| | } |
| | .... |
| VNF Configurable Properties | isAutohealEnabled=True |
| | .... |
+-----------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------+
Auto Healing¶
When fault events occur in VIM, ServerNotifier notifies fault event to Tacker via the FaultNotification interface.
Tacker checks fault_id
attribute in the fault event and determines
whether AutoHealing should be performed. In case of performing
AutoHealing, VMs are deleted and created via Heat. The client is
no need to handle healing.
Using Vendor Specific Plugin¶
ServerNotification plugin can be replaced with a vendor specific function. To replace a plugin, change the configurations below. The replaced class must be a subclass of tacker.sol_refactored.common.monitoring_plugin_base.MonitoringPlugin.
Configuration (CONF.server_notification) |
Default |
Description |
---|---|---|
|
tacker.sol_refactored.common.server_notification |
Package name for server notification. |
|
ServerNotification |
Class name for server notification. |
Error-handling¶
This chapter introduces how to perform error-handling if the LCM fails in the FaultNotification function.
The LCM of the FaultNotification function will use MgmtDriver, so if the user wants to call MgmtDriver in the rollback operation of error-handling, the VNF Package needs to be modified in advance.
For the specific modification method, please refer to
Error-handling of MgmtDriver
in ETSI NFV-SOL VNF error-handling.
Note
After modifying the VNF Package, LCM can be performed normally. If the LCM fails, the user can perform error-handling operations.
For details, please refer to the content of
Retry VNF LCM Operation
and Rollback VNF LCM Operation
in
ETSI NFV-SOL VNF error-handling.