Set the volume driver to the Storwize family and SVC
                driver by setting the volume_driver
                option in cinder.conf as
                follows:
volume_driver = cinder.volume.drivers.ibm.storwize_svc.StorwizeSVCDriver
The following options specify default values for all volumes. Some can be over-ridden using volume types, which are described below.
| Flag name | Type | Default | Description | ||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
  | 
                        Required  | 
                        Management IP or host name  | 
                    |||||||||||||||||||||||||||||||||||||||||||||||
  | 
                        Optional  | 
                        22  | 
                        Management port  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
  | 
                        Required  | 
                        Management login username  | 
                    |||||||||||||||||||||||||||||||||||||||||||||||
  | 
                        Required [a]  | 
                        Management login password  | 
                    |||||||||||||||||||||||||||||||||||||||||||||||
  | 
                        Required [a]  | 
                        Management login SSH private key  | 
                    |||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Required  | 
                        Default pool name for volumes  | 
                    |||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        2  | 
                        Initial physical allocation (percentage) [b]  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        0 (disabled)  | 
                        Space allocation warning threshold (percentage) [b]  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        True  | 
                        Enable or disable volume auto expand [c]  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        256  | 
                        Volume grain size [b] in KB  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        False  | 
                        Enable or disable Real-time Compression [d]  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        True  | 
                        Enable or disable Easy Tier [e]  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        0  | 
                        The I/O group in which to allocate vdisks  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        120  | 
                        FlashCopy timeout threshold [f] (seconds)  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        iSCSI  | 
                        Connection protocol to use (currently supports 'iSCSI' or 'FC')  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        True  | 
                        Configure CHAP authentication for iSCSI connections  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        False  | 
                        Enable multipath for FC connections [g]  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
                                  | 
                        Optional  | 
                        True  | 
                        Enable mapping vdisks to multiple hosts [h]  | 
                    ||||||||||||||||||||||||||||||||||||||||||||||
[a] The authentication requires
                                   either a password
                                   ( [b] The driver creates
                                   thin-provisioned volumes by
                                   default. The
                                    [c] Defines whether
                                   thin-provisioned volumes can be
                                   auto expanded by the storage
                                   system, a value of
                                    [d] Defines whether Real-time Compression is used for the volumes created with OpenStack. Details on Real-time Compression can be found in the Storwize family and SVC documentation. The Storwize or SVC system must have compression enabled for this feature to work. [e] Defines whether Easy Tier is used for the volumes created with OpenStack. Details on EasyTier can be found in the Storwize family and SVC documentation. The Storwize or SVC system must have Easy Tier enabled for this feature to work. [f] The driver wait timeout threshold when creating an OpenStack snapshot. This is actually the maximum amount of time that the driver waits for the Storwize family or SVC system to prepare a new FlashCopy mapping. The driver accepts a maximum wait time of 600 seconds (10 minutes). [g] Multipath for iSCSI connections requires no storage-side configuration and is enabled if the compute host has multipath configured. [h] This option allows the driver to map a vdisk to more than one host at a time. This scenario occurs during migration of a virtual machine with an attached volume; the volume is simultaneously mapped to both the source and destination compute hosts. If your deployment does not require attaching vdisks to multiple hosts, setting this flag to False will provide added safety.  | |||||||||||||||||||||||||||||||||||||||||||||||||
| Configuration option = Default value | Description | 
|---|---|
| [DEFAULT] | |
| storwize_svc_allow_tenant_qos = False | (BoolOpt) Allow tenants to specify QOS on create | 
| storwize_svc_connection_protocol = iSCSI | (StrOpt) Connection protocol (iSCSI/FC) | 
| storwize_svc_flashcopy_timeout = 120 | (IntOpt) Maximum number of seconds to wait for FlashCopy to be prepared. Maximum value is 600 seconds (10 minutes) | 
| storwize_svc_iscsi_chap_enabled = True | (BoolOpt) Configure CHAP authentication for iSCSI connections (Default: Enabled) | 
| storwize_svc_multihostmap_enabled = True | (BoolOpt) Allows vdisk to multi host mapping | 
| storwize_svc_multipath_enabled = False | (BoolOpt) Connect with multipath (FC only; iSCSI multipath is controlled by Nova) | 
| storwize_svc_npiv_compatibility_mode = False | (BoolOpt) Indicate whether svc driver is compatible for NPIV setup. If it is compatible, it will allow no wwpns being returned on get_conn_fc_wwpns during initialize_connection | 
| storwize_svc_stretched_cluster_partner = None | (StrOpt) If operating in stretched cluster mode, specify the name of the pool in which mirrored copies are stored.Example: "pool2" | 
| storwize_svc_vol_autoexpand = True | (BoolOpt) Storage system autoexpand parameter for volumes (True/False) | 
| storwize_svc_vol_compression = False | (BoolOpt) Storage system compression option for volumes | 
| storwize_svc_vol_easytier = True | (BoolOpt) Enable Easy Tier for volumes | 
| storwize_svc_vol_grainsize = 256 | (IntOpt) Storage system grain size parameter for volumes (32/64/128/256) | 
| storwize_svc_vol_iogrp = 0 | (IntOpt) The I/O group in which to allocate volumes | 
| storwize_svc_vol_rsize = 2 | (IntOpt) Storage system space-efficiency parameter for volumes (percentage) | 
| storwize_svc_vol_warning = 0 | (IntOpt) Storage system threshold for volume capacity warnings (percentage) | 
| storwize_svc_volpool_name = volpool | (StrOpt) Storage system storage pool for volumes | 
The IBM Storwize/SVC driver exposes capabilities
                that can be added to the extra
                    specs of volume types, and used by the
                filter scheduler to determine placement of new
                volumes. Make sure to prefix these keys with
                    capabilities: to indicate that
                the scheduler should use them. The following
                    extra specs are
                supported:
capabilities:volume_back-end_name - Specify a specific back-end where the volume should be created. The back-end name is a concatenation of the name of the IBM Storwize/SVC storage system as shown in
lssystem, an underscore, and the name of the pool (mdisk group). For example:capabilities:volume_back-end_name=myV7000_openstackpool
capabilities:compression_support - Specify a back-end according to compression support. A value of
Trueshould be used to request a back-end that supports compression, and a value ofFalsewill request a back-end that does not support compression. If you do not have constraints on compression support, do not set this key. Note that specifyingTruedoes not enable compression; it only requests that the volume be placed on a back-end that supports compression. Example syntax:capabilities:compression_support='<is> True'
capabilities:easytier_support - Similar semantics as the
compression_supportkey, but for specifying according to support of the Easy Tier feature. Example syntax:capabilities:easytier_support='<is> True'
capabilities:storage_protocol - Specifies the connection protocol used to attach volumes of this type to instances. Legal values are
iSCSIandFC. Thisextra specsvalue is used for both placement and setting the protocol used for this volume. In the example syntax, note <in> is used as opposed to <is> used in the previous examples.capabilities:storage_protocol='<in> FC'
Volume types can also be used to pass options to the IBM Storwize/SVC driver, which over-ride the default values set in the configuration file. Contrary to the previous examples where the "capabilities" scope was used to pass parameters to the Cinder scheduler, options can be passed to the IBM Storwize/SVC driver with the "drivers" scope.
The following extra specs keys
                are supported by the IBM Storwize/SVC driver:
rsize
warning
autoexpand
grainsize
compression
easytier
multipath
iogrp
These keys have the same semantics as their
                counterparts in the configuration file. They are set
                similarly; for example, rsize=2 or
                    compression=False.
In the following example, we create a volume type to specify a controller that supports iSCSI and compression, to use iSCSI when attaching the volume, and to enable compression:
$ cinder type-create compressed $ cinder type-key compressed set capabilities:storage_protocol='<in> iSCSI' capabilities:compression_support='<is> True' drivers:compression=True
We can then create a 50GB volume using this type:
$ cinder create --display-name "compressed volume" --volume-type compressed 50
Volume types can be used, for example, to provide users with different
performance levels (such as, allocating entirely on an HDD tier, using Easy Tier for an HDD-SDD mix, or allocating entirely on an SSD tier)
resiliency levels (such as, allocating volumes in pools with different RAID levels)
features (such as, enabling/disabling Real-time Compression)